Bafang Error Code Error 10 / 10H Fix & Diagnostic Guide
Motor Internal Temperature Sensor Protection Active — BBSHD / M620 Ultra / M510 / M820
Fault Symptoms & Root Cause
Symptoms: Motor assist cuts out; display shows Error 10 or flashes temperature icon.
Primary Cause: Internal thermistor inside motor core detected winding temperatures exceeding 130°C.
Step-by-Step DIY Diagnostic & Repair Protocol
- Park the bike in the shade and allow motor housing to cool down for 20 minutes.
- Check that crank arms spin smoothly without mechanical binding.
- Select a lower gear when climbing to maintain higher pedaling cadence (80+ RPM).
- If motor case feels completely cold but error persists, internal thermistor wiring is open.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Measure resistance of White wire on hall harness to Ground: reading should be 8k - 12k Ohms at room temperature.
Required Diagnostic Tools: Digital Multimeter, Hex Key Set, Terminal Probe
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Temp Sensor (White) | NTC Thermistor | 10k Ohms @ 25°C / < 1k Ohms when hot |
Frequently Asked Questions
What does Bafang Error Error 10 / 10H mean?
Motor Internal Temperature Sensor Protection Active on BBSHD / M620 Ultra / M510 / M820. Symptoms include Motor assist cuts out; display shows Error 10 or flashes temperature icon.. The root fault is: Internal thermistor inside motor core detected winding temperatures exceeding 130°C.
How do I diagnose and fix Bafang Error Error 10 / 10H?
Park the bike in the shade and allow motor housing to cool down for 20 minutes. Check that crank arms spin smoothly without mechanical binding. Select a lower gear when climbing to maintain higher pedaling cadence (80+ RPM). If motor case feels completely cold but error persists, internal thermistor wiring is open.
What multimeter voltage should I read during testing?
Target voltage is 10k Ohms @ 25°C / < 1k Ohms when hot. Follow the test procedure: Measure resistance of White wire on hall harness to Ground: reading should be 8k - 12k Ohms at room temperature.
Other Bafang Error Codes
Display to Controller Communication Loss Bafang E21 / 21
Speed Sensor Cable Abnormality Bafang E08 / 08
Motor Internal Hall Sensor Signal Abnormality Bafang 07 / 007
High Voltage Protection / Battery Low Voltage Cutoff Bafang Error 09 / E09 / 09H
Motor Phase Line Open Circuit or MOSFET Short Bafang 06 / E06
Low Voltage Protection / Battery Discharged