Bosch Error Code 414 Fix & Diagnostic Guide
Operating Unit Connection or Internal Keypad Fault — Active Line / Performance Line / CX (Purion, Intuvia, Kiox)
Fault Symptoms & Root Cause
Symptoms: Drive assist does not engage, display buttons unresponsive, error 414 intermittently flashes on Purion or Intuvia.
Primary Cause: Corroded or loose contacts between display mount plate and handlebar wiring, or sticky push-button switch in the remote unit.
Step-by-Step DIY Diagnostic & Repair Protocol
- Power down system completely.
- Unclip Intuvia or Kiox display from shoe mount. Clean gold pins with isopropyl alcohol and a clean microfiber cloth.
- Check that mount mounting screws are not overtightened (causes PCB warping and pin lift).
- Inspect Purion integrated thumb remote for sticky buttons or water trapped behind membrane.
- Reseat firmly and restart system.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Measure pin 1 to pin 4 on mounting shoe: 12V DC indicates motor wiring intact. Inspect spring contacts for depression.
Required Diagnostic Tools: Torx T20 Screwdriver
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Pin 1 | VCC (12V Supply to HMI) | 10.8V - 12.6V DC |
| Pin Pin 2 | CAN-H (Controller Area Network High) | 2.5V - 3.5V Oscillating |
| Pin Pin 3 | CAN-L (Controller Area Network Low) | 1.5V - 2.5V Oscillating |
| Pin Pin 4 | GND (Common Ground) | 0.0V Ground Reference |
Frequently Asked Questions
What does Bosch Error 414 mean?
Operating Unit Connection or Internal Keypad Fault on Active Line / Performance Line / CX (Purion, Intuvia, Kiox). Symptoms include Drive assist does not engage, display buttons unresponsive, error 414 intermittently flashes on Purion or Intuvia.. The root fault is: Corroded or loose contacts between display mount plate and handlebar wiring, or sticky push-button switch in the remote unit.
How do I diagnose and fix Bosch Error 414?
Power down system completely. Unclip Intuvia or Kiox display from shoe mount. Clean gold pins with isopropyl alcohol and a clean microfiber cloth. Check that mount mounting screws are not overtightened (causes PCB warping and pin lift). Inspect Purion integrated thumb remote for sticky buttons or water trapped behind membrane. Reseat firmly and restart system.
What multimeter voltage should I read during testing?
Target voltage is 10.8V - 12.6V DC. Follow the test procedure: Measure pin 1 to pin 4 on mounting shoe: 12V DC indicates motor wiring intact. Inspect spring contacts for depression.
Other Bosch Error Codes
Speed Sensor Signal Failure Bosch 500 / 500111
Internal Drive Unit Hardware General Error (Smart System: 500111) Bosch 510
Internal Drive Unit Torque / Sensor Plausibility Fault Bosch 504
Tuning Dongle / Tamper Algorithm Lockout Bosch 530
Battery Management System (BMS) Connection Fault Bosch 540
Drive Unit Internal Temperature Cut-Off / Stator Overheat