Bosch Error Code 418 Fix & Diagnostic Guide
Display Unit Internal Micro-Battery Depleted — Intuvia / Purion / Kiox / Nyon Display
Fault Symptoms & Root Cause
Symptoms: Display immediately shuts off when bike is switched off, clock resets to 12:00, refuses to boot without main battery.
Primary Cause: Internal CR2016 / 3.7V Li-Po coin cell inside Intuvia or Nyon is completely dead from prolonged winter storage.
Step-by-Step DIY Diagnostic & Repair Protocol
- On Intuvia displays: remove rubber hatch on back to inspect replaceable CR2016 cell.
- Replace with fresh CR2016 battery (+ terminal facing outwards).
- Alternatively, connect display to micro-USB 5V charger for 1 hour to recharge.
- Mount onto bike, power on main Bosch PowerPack or PowerTube battery.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Check coin cell voltage with multimeter on DC 20V scale. Under 2.8V causes immediate loss of clock and display memory.
Required Diagnostic Tools: Small Coin or Flathead Screwdriver
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin CR2016 + | Internal RTC & SRAM Keeper | 3.0V - 3.2V DC |
| Pin Micro-USB Pin 1 | 5V Charge In | 4.75V - 5.25V DC |
Frequently Asked Questions
What does Bosch Error 418 mean?
Display Unit Internal Micro-Battery Depleted on Intuvia / Purion / Kiox / Nyon Display. Symptoms include Display immediately shuts off when bike is switched off, clock resets to 12:00, refuses to boot without main battery.. The root fault is: Internal CR2016 / 3.7V Li-Po coin cell inside Intuvia or Nyon is completely dead from prolonged winter storage.
How do I diagnose and fix Bosch Error 418?
On Intuvia displays: remove rubber hatch on back to inspect replaceable CR2016 cell. Replace with fresh CR2016 battery (+ terminal facing outwards). Alternatively, connect display to micro-USB 5V charger for 1 hour to recharge. Mount onto bike, power on main Bosch PowerPack or PowerTube battery.
What multimeter voltage should I read during testing?
Target voltage is 3.0V - 3.2V DC. Follow the test procedure: Check coin cell voltage with multimeter on DC 20V scale. Under 2.8V causes immediate loss of clock and display memory.
Other Bosch Error Codes
Speed Sensor Signal Failure Bosch 500 / 500111
Internal Drive Unit Hardware General Error (Smart System: 500111) Bosch 510
Internal Drive Unit Torque / Sensor Plausibility Fault Bosch 504
Tuning Dongle / Tamper Algorithm Lockout Bosch 530
Battery Management System (BMS) Connection Fault Bosch 540
Drive Unit Internal Temperature Cut-Off / Stator Overheat