Bosch Error Code 418 Fix & Diagnostic Guide

Display Unit Internal Micro-Battery Depleted — Intuvia / Purion / Kiox / Nyon Display

Severity: Advisory • Difficulty: 5-min DIY Workshop • Voltage Target: 3.0V - 3.2V DC

Fault Symptoms & Root Cause

Symptoms: Display immediately shuts off when bike is switched off, clock resets to 12:00, refuses to boot without main battery.

Primary Cause: Internal CR2016 / 3.7V Li-Po coin cell inside Intuvia or Nyon is completely dead from prolonged winter storage.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. On Intuvia displays: remove rubber hatch on back to inspect replaceable CR2016 cell.
  2. Replace with fresh CR2016 battery (+ terminal facing outwards).
  3. Alternatively, connect display to micro-USB 5V charger for 1 hour to recharge.
  4. Mount onto bike, power on main Bosch PowerPack or PowerTube battery.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Check coin cell voltage with multimeter on DC 20V scale. Under 2.8V causes immediate loss of clock and display memory.

Required Diagnostic Tools: Small Coin or Flathead Screwdriver

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin CR2016 + Internal RTC & SRAM Keeper 3.0V - 3.2V DC
Pin Micro-USB Pin 1 5V Charge In 4.75V - 5.25V DC

Frequently Asked Questions

What does Bosch Error 418 mean?

Display Unit Internal Micro-Battery Depleted on Intuvia / Purion / Kiox / Nyon Display. Symptoms include Display immediately shuts off when bike is switched off, clock resets to 12:00, refuses to boot without main battery.. The root fault is: Internal CR2016 / 3.7V Li-Po coin cell inside Intuvia or Nyon is completely dead from prolonged winter storage.

How do I diagnose and fix Bosch Error 418?

On Intuvia displays: remove rubber hatch on back to inspect replaceable CR2016 cell. Replace with fresh CR2016 battery (+ terminal facing outwards). Alternatively, connect display to micro-USB 5V charger for 1 hour to recharge. Mount onto bike, power on main Bosch PowerPack or PowerTube battery.

What multimeter voltage should I read during testing?

Target voltage is 3.0V - 3.2V DC. Follow the test procedure: Check coin cell voltage with multimeter on DC 20V scale. Under 2.8V causes immediate loss of clock and display memory.

Other Bosch Error Codes

Bosch 503
Speed Sensor Signal Failure
Bosch 500 / 500111
Internal Drive Unit Hardware General Error (Smart System: 500111)
Bosch 510
Internal Drive Unit Torque / Sensor Plausibility Fault
Bosch 504
Tuning Dongle / Tamper Algorithm Lockout
Bosch 530
Battery Management System (BMS) Connection Fault
Bosch 540
Drive Unit Internal Temperature Cut-Off / Stator Overheat