Bosch Error Code 514003 Fix & Diagnostic Guide

ABS Can-FD Packet Loss Rate High — Smart System BDU3741 / ABS 2.0 / Performance Line CX

Severity: Warning (Assistance Reduced) • Difficulty: 15-min DIY Workshop • Voltage Target: 11.6V - 12.4V DC

Fault Symptoms & Root Cause

Symptoms: ABS light flickers intermittently over bumpy terrain.

Primary Cause: Water inside 4-pin ABS motor harness connector.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Connect Bosch eBike Flow App to read freeze-frame data for DTC 514003.
  2. Inspect wiring harness connectors at bottom bracket motor ports.
  3. Check 5V DC reference and CAN-FD signal voltages with digital multimeter.
  4. Perform power cycle reset: press and hold LED Remote power button for 10 seconds.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure CAN-FD signal pins: CAN-H (2.5V nominal, pulses up to 3.5V during transmission), CAN-L (2.5V nominal, pulses down to 1.5V). 12V DC bus on pin 1.

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) 12V Auxiliary Supply 11.6V - 12.4V DC
Pin Pin 2 (Black) Ground 0.0V Ground
Pin Pin 3 (Orange) CAN-FD High 2.4V - 3.5V DC
Pin Pin 4 (Yellow) CAN-FD Low 1.5V - 2.5V DC

Frequently Asked Questions

What does Bosch Error 514003 mean?

ABS Can-FD Packet Loss Rate High on Smart System BDU3741 / ABS 2.0 / Performance Line CX. Symptoms include ABS light flickers intermittently over bumpy terrain.. The root fault is: Water inside 4-pin ABS motor harness connector.

How do I diagnose and fix Bosch Error 514003?

Connect Bosch eBike Flow App to read freeze-frame data for DTC 514003. Inspect wiring harness connectors at bottom bracket motor ports. Check 5V DC reference and CAN-FD signal voltages with digital multimeter. Perform power cycle reset: press and hold LED Remote power button for 10 seconds.

What multimeter voltage should I read during testing?

Target voltage is 11.6V - 12.4V DC. Follow the test procedure: Measure CAN-FD signal pins: CAN-H (2.5V nominal, pulses up to 3.5V during transmission), CAN-L (2.5V nominal, pulses down to 1.5V). 12V DC bus on pin 1.

Other Bosch Error Codes

Bosch 503
Speed Sensor Signal Failure
Bosch 500 / 500111
Internal Drive Unit Hardware General Error (Smart System: 500111)
Bosch 510
Internal Drive Unit Torque / Sensor Plausibility Fault
Bosch 504
Tuning Dongle / Tamper Algorithm Lockout
Bosch 530
Battery Management System (BMS) Connection Fault
Bosch 540
Drive Unit Internal Temperature Cut-Off / Stator Overheat