Bosch Error Code 870 Fix & Diagnostic Guide

Drive Unit Angular Velocity Sensor Fault — Smart System / Performance CX / Active Line

Severity: Critical (Fatal Drive Stop) • Difficulty: Advanced Workshop • Voltage Target: 5.0V +/- 0.15V DC

Fault Symptoms & Root Cause

Symptoms: Motor vibrates violently on start-up and shuts down.

Primary Cause: Rotor angle resolver / Hall sensors out of phase.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Inspect 870 electrical harness connectors for bent pins, water droplets, or corrosion.
  2. Cycle bike power completely: hold power button for 10 seconds to discharge system bus.
  3. Check 5V DC reference voltage at diagnostic port using digital multimeter.
  4. Ensure eBike Flow App has installed latest firmware updates across all modules.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Check 5V DC between red power pin and black ground pin at sensor harness. Must measure steady 4.85V to 5.15V DC. Check signal line with multimeter on diode check mode.

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) VCC Logic Power 5.0V +/- 0.15V DC
Pin Pin 2 (Black) Ground Reference 0.0V DC Ground
Pin Pin 3 (Orange/White) CAN-High / Data Out 2.3V - 2.7V DC
Pin Pin 4 (Yellow/Blue) CAN-Low / Signal In 2.1V - 2.5V DC

Frequently Asked Questions

What does Bosch Error 870 mean?

Drive Unit Angular Velocity Sensor Fault on Smart System / Performance CX / Active Line. Symptoms include Motor vibrates violently on start-up and shuts down.. The root fault is: Rotor angle resolver / Hall sensors out of phase.

How do I diagnose and fix Bosch Error 870?

Inspect 870 electrical harness connectors for bent pins, water droplets, or corrosion. Cycle bike power completely: hold power button for 10 seconds to discharge system bus. Check 5V DC reference voltage at diagnostic port using digital multimeter. Ensure eBike Flow App has installed latest firmware updates across all modules.

What multimeter voltage should I read during testing?

Target voltage is 5.0V +/- 0.15V DC. Follow the test procedure: Check 5V DC between red power pin and black ground pin at sensor harness. Must measure steady 4.85V to 5.15V DC. Check signal line with multimeter on diode check mode.

Other Bosch Error Codes

Bosch 503
Speed Sensor Signal Failure
Bosch 500 / 500111
Internal Drive Unit Hardware General Error (Smart System: 500111)
Bosch 510
Internal Drive Unit Torque / Sensor Plausibility Fault
Bosch 504
Tuning Dongle / Tamper Algorithm Lockout
Bosch 530
Battery Management System (BMS) Connection Fault
Bosch 540
Drive Unit Internal Temperature Cut-Off / Stator Overheat