Brose Error Code 101 Fix & Diagnostic Guide

Battery Pack Discharge Undervoltage Protection Cutoff — Drive C / Drive T / Drive S / Drive S Mag

Severity: Warning (Assistance Disabled) • Difficulty: 5-min Trailside • Voltage Target: Full: 41.8V - 42.0V DC / Cutoff: 31.0V DC

Fault Symptoms & Root Cause

Symptoms: Motor assist cuts out; display shows code 101 or battery empty icon.

Primary Cause: Battery state of charge has depleted below minimum safety threshold (typically ~31.0V on a 36V system) or severe cell voltage sag under load.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Plug battery into OEM charger and recharge to 100%.
  2. Allow battery to remain on charger for 1–2 hours after full charge to balance individual cell series.
  3. If 101 triggers on a battery that displays 50%+ charge, one parallel cell group is degraded.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure open circuit voltage with multimeter. Voltage under 32V requires immediate recharge.

Required Diagnostic Tools: Digital Multimeter

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Battery Output + Positive Terminal Full: 41.8V - 42.0V DC / Cutoff: 31.0V DC
Pin Battery Output - Ground Terminal 0.0V DC

Frequently Asked Questions

What does Brose Error 101 mean?

Battery Pack Discharge Undervoltage Protection Cutoff on Drive C / Drive T / Drive S / Drive S Mag. Symptoms include Motor assist cuts out; display shows code 101 or battery empty icon.. The root fault is: Battery state of charge has depleted below minimum safety threshold (typically ~31.0V on a 36V system) or severe cell voltage sag under load.

How do I diagnose and fix Brose Error 101?

Plug battery into OEM charger and recharge to 100%. Allow battery to remain on charger for 1–2 hours after full charge to balance individual cell series. If 101 triggers on a battery that displays 50%+ charge, one parallel cell group is degraded.

What multimeter voltage should I read during testing?

Target voltage is Full: 41.8V - 42.0V DC / Cutoff: 31.0V DC. Follow the test procedure: Measure open circuit voltage with multimeter. Voltage under 32V requires immediate recharge.

Other Brose Error Codes

Brose 001 / C180
Motor Stator Temperature Thermal Cutoff
Brose 006
Speed Sensor Input Timeout Fault
Brose 30
Display Communication Lost
Brose 201
CAN-Bus Frame Communication Heartbeat Timeout
Brose 10
Torque Sensor Signal Drift
Brose 11
Cadence Hall Sensor Direction Error