Fazua Error Code 01 Fix & Diagnostic Guide

Drivepack Drive Unit Mechanical Lock Open — Ride 60 / Ride 50 / Evation

Severity: Warning (Assistance Offline) • Difficulty: 5-min Trailside • Voltage Target: 4.9V - 5.1V DC

Fault Symptoms & Root Cause

Symptoms: LEDs flash red; motor assist will not start.

Primary Cause: Drivepack cylinder not locked into frame downtube latch mechanism.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Remove Drivepack and inspect bottom bracket interface gold contact pins for 01.
  2. Clean pogo pins with isopropyl alcohol and verify spring return on every pin.
  3. Check rear wheel spoke/disc magnet alignment with chainstay sensor (gap < 4mm).
  4. Connect bike via USB to Fazua Toolbox software on PC/Mac to view diagnostic log.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure voltage at bottom bracket connector interface pins: 5V DC logic power, 0V ground, CAN bus lines 2.5V differential.

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Gold Pogo) 5V Logic Supply 4.9V - 5.1V DC
Pin Pin 2 (Gold Pogo) Ground 0.0V Ground
Pin Pin 3 (Gold Pogo) CAN High 2.4V - 2.8V DC
Pin Pin 4 (Gold Pogo) CAN Low 2.1V - 2.5V DC

Frequently Asked Questions

What does Fazua Error 01 mean?

Drivepack Drive Unit Mechanical Lock Open on Ride 60 / Ride 50 / Evation. Symptoms include LEDs flash red; motor assist will not start.. The root fault is: Drivepack cylinder not locked into frame downtube latch mechanism.

How do I diagnose and fix Fazua Error 01?

Remove Drivepack and inspect bottom bracket interface gold contact pins for 01. Clean pogo pins with isopropyl alcohol and verify spring return on every pin. Check rear wheel spoke/disc magnet alignment with chainstay sensor (gap < 4mm). Connect bike via USB to Fazua Toolbox software on PC/Mac to view diagnostic log.

What multimeter voltage should I read during testing?

Target voltage is 4.9V - 5.1V DC. Follow the test procedure: Measure voltage at bottom bracket connector interface pins: 5V DC logic power, 0V ground, CAN bus lines 2.5V differential.

Other Fazua Error Codes

Fazua Error 102
Bottom Bracket Torque Sensor Calibration Offset
Fazua C200
Bottom Bracket Torque Sensor Signal Out of Bounds
Fazua 02
Bottom Bracket Cadence / Torque Sensor Communication Error
Fazua 03
Battery BMS Communication Timeout
Fazua 04
Motor Core Over-Temperature Shutdown
Fazua 05
Ring Control / Remote Communication Timeout