Generic OEM / KT / SW Error Code Error 02 / Info 02 / 02H Fix & Diagnostic Guide
Brake Cutoff Switch Active / Stuck Closed — KT-LCD3 / KT-LCD5 / SW900 / S866 / S830 / King-Meter / Key-Disp
Fault Symptoms & Root Cause
Symptoms: Brake icon stays on LCD screen; throttle and pedal assist do not work.
Primary Cause: One of the brake cut-off switches in the left or right lever is stuck in the closed position, keeping motor interlock engaged.
Step-by-Step DIY Diagnostic & Repair Protocol
- Check both brake levers to make sure they return completely to the resting position.
- Unplug the 2-pin red waterproof brake sensor connectors on the handlebars one at a time.
- If unplugging one connector clears Error 02, that brake lever sensor is defective.
- For hydraulic add-on magnet sensors, adjust magnet to sensor distance to 2mm.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Check continuity across sensor with multimeter. Must be open circuit when lever is released; 0 Ohms when lever pulled.
Required Diagnostic Tools: Digital Multimeter, Hex Key Set, Terminal Probe
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Pin 1 | Sense Voltage | 5.0V DC |
| Pin Pin 2 | Ground | 0.0V DC |
Frequently Asked Questions
What does Generic OEM / KT / SW Error Error 02 / Info 02 / 02H mean?
Brake Cutoff Switch Active / Stuck Closed on KT-LCD3 / KT-LCD5 / SW900 / S866 / S830 / King-Meter / Key-Disp. Symptoms include Brake icon stays on LCD screen; throttle and pedal assist do not work.. The root fault is: One of the brake cut-off switches in the left or right lever is stuck in the closed position, keeping motor interlock engaged.
How do I diagnose and fix Generic OEM / KT / SW Error Error 02 / Info 02 / 02H?
Check both brake levers to make sure they return completely to the resting position. Unplug the 2-pin red waterproof brake sensor connectors on the handlebars one at a time. If unplugging one connector clears Error 02, that brake lever sensor is defective. For hydraulic add-on magnet sensors, adjust magnet to sensor distance to 2mm.
What multimeter voltage should I read during testing?
Target voltage is 5.0V DC. Follow the test procedure: Check continuity across sensor with multimeter. Must be open circuit when lever is released; 0 Ohms when lever pulled.
Other Generic OEM / KT / SW Error Codes
Battery Low Voltage Cutoff Protection Generic OEM / KT / SW E01 / E1 / Error 01 / Info 01
Throttle Signal Abnormality & Boot-Up Voltage Lockout Generic OEM / KT / SW Error 03 / Info 03 / 03H
PAS Pedal Assist Cadence Sensor Signal Failure Generic OEM / KT / SW Error 07 / Info 07 / 07H
Motor Phase Line Disconnected or Short Circuit Generic OEM / KT / SW Error 10 / Info 10 / 10H
Display Communication Receiving Failure Generic OEM / KT / SW Error 30 / Info 30 / 30H
UART Communication Timeout Between LCD and Controller