Mahle Error Code Error 10 Fix & Diagnostic Guide

PAS Cadence Sensor Frequency Signal Fault — X35 / X35+ / X20 Rear Hub System

Severity: Warning (Assistance Reduced) • Difficulty: 15-min DIY Workshop • Voltage Target: 5.0V DC

Fault Symptoms & Root Cause

Symptoms: iWoc top tube button flashes pink/red; hub motor will not engage when pedaling forward.

Primary Cause: Bottom bracket lockring magnetic PAS disc signal missing or out of range.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Inspect bottom bracket lockring for loose magnetic ring gear or missing magnet teeth.
  2. Verify PAS sensor wire routing under non-drive side bottom bracket shell for damage.
  3. Clean dirt and oil slurry from sensor head surface.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Spin cranks slowly backwards and forwards. Dual quadrature Hall signals must alternate.

Required Diagnostic Tools: Bottom Bracket Tool for Hollowtech II / Mahle Lockring

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) 5V Sensor Power 5.0V DC
Pin Pin 2 (White) Quad Cadence Signal A 0/5V Pulse Frequency
Pin Pin 3 (Green) Quad Cadence Signal B 0/5V Pulse Frequency (90° Offset)

Frequently Asked Questions

What does Mahle Error Error 10 mean?

PAS Cadence Sensor Frequency Signal Fault on X35 / X35+ / X20 Rear Hub System. Symptoms include iWoc top tube button flashes pink/red; hub motor will not engage when pedaling forward.. The root fault is: Bottom bracket lockring magnetic PAS disc signal missing or out of range.

How do I diagnose and fix Mahle Error Error 10?

Inspect bottom bracket lockring for loose magnetic ring gear or missing magnet teeth. Verify PAS sensor wire routing under non-drive side bottom bracket shell for damage. Clean dirt and oil slurry from sensor head surface.

What multimeter voltage should I read during testing?

Target voltage is 5.0V DC. Follow the test procedure: Spin cranks slowly backwards and forwards. Dual quadrature Hall signals must alternate.

Other Mahle Error Codes

Mahle Error 02
Battery Pack Over-Temperature
Mahle Error 01 / Pink Blink
iWoc Handlebar / Top Tube Button Signal Loss
Mahle Error 16 / Err 16
Rear Hub Motor Hall Sensor Failure
Mahle Error 03
Motor Rear Hub Hall Sensor Failure
Mahle Error 04
Torque / PAS Sensor Signal Missing
Mahle Error 05
Controller Over-Current Protection