Bafang Error Code Error 11 Fix & Diagnostic Guide

Motor Temperature Sensor Circuit Open — BBS01 / BBS02 / BBSHD / M500 / M510 / M620 / M820

Severity: Informational / Warning • Difficulty: 15-min DIY Workshop • Voltage Target: 4.8V - 5.1V DC

Fault Symptoms & Root Cause

Symptoms: Assist works but Error 11 flashes on DPC-18 / 850C display.

Primary Cause: White temperature sensor wire inside motor harness severed or thermistor cracked.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Check main 1T4 wiring harness and green/yellow waterproof Julet connectors for Error 11.
  2. Separate connector, inspect for pushed-back gold pins, blow out water, and apply dielectric grease.
  3. Perform multimeter voltage check on 5V sensor power rail.
  4. For Hall sensor errors, test Hall signal pins using 5V pull-up bench test while spinning motor.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure DC voltage between Red (5V) and Black (GND) on throttle/sensor plug. Must read 4.3V to 5.0V. Test signal wire (0.8V to 4.2V variable).

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) 5V Sensor Power 4.8V - 5.1V DC
Pin Pin 2 (Black) Ground Reference 0.0V Ground
Pin Pin 3 (White) Speed / Hall Signal 0V / 5V Pulse Toggle
Pin Pin 4 (Green) UART TX / CAN-H 2.5V - 3.3V Logic
Pin Pin 5 (Yellow) UART RX / CAN-L 2.5V - 3.3V Logic

Frequently Asked Questions

What does Bafang Error Error 11 mean?

Motor Temperature Sensor Circuit Open on BBS01 / BBS02 / BBSHD / M500 / M510 / M620 / M820. Symptoms include Assist works but Error 11 flashes on DPC-18 / 850C display.. The root fault is: White temperature sensor wire inside motor harness severed or thermistor cracked.

How do I diagnose and fix Bafang Error Error 11?

Check main 1T4 wiring harness and green/yellow waterproof Julet connectors for Error 11. Separate connector, inspect for pushed-back gold pins, blow out water, and apply dielectric grease. Perform multimeter voltage check on 5V sensor power rail. For Hall sensor errors, test Hall signal pins using 5V pull-up bench test while spinning motor.

What multimeter voltage should I read during testing?

Target voltage is 4.8V - 5.1V DC. Follow the test procedure: Measure DC voltage between Red (5V) and Black (GND) on throttle/sensor plug. Must read 4.3V to 5.0V. Test signal wire (0.8V to 4.2V variable).

Other Bafang Error Codes

Bafang E30 / 30
Display to Controller Communication Loss
Bafang E21 / 21
Speed Sensor Cable Abnormality
Bafang E08 / 08
Motor Internal Hall Sensor Signal Abnormality
Bafang 07 / 007
High Voltage Protection / Battery Low Voltage Cutoff
Bafang Error 09 / E09 / 09H
Motor Phase Line Open Circuit or MOSFET Short
Bafang 06 / E06
Low Voltage Protection / Battery Discharged