Tenways Error Code Fault 01 Fix & Diagnostic Guide

Mivice Torque Sensor Pulse / Offset Irregularity — Tenways Mivice Drive System (CGO600, CGO800S, AGO X)

Severity: Warning (Assistance Reduced) • Difficulty: 5-min Trailside • Voltage Target: +5.0V DC

Fault Symptoms & Root Cause

Symptoms: Smooth belt drive assistance stops working; OLED screen shows Fault 01.

Primary Cause: Bottom bracket integrated Mivice torque sensor cable dislodged or zero-offset drifted outside factory tolerances.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Power cycle bike without touching pedals.
  2. Trace the thin sensor wire coming from bottom bracket down into frame port.
  3. Verify bottom bracket has no lateral play; tighten bottom bracket lockring if loose.
  4. Check smartphone app for Mivice firmware recalibration function.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure voltage between Pin 2 and Pin 3 while resting. Voltage must be steady at 1.5V +/- 0.1V.

Required Diagnostic Tools: Bottom Bracket Tool & Crank Puller

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) 5V Sensor Power +5.0V DC
Pin Pin 2 (Black) Ground 0.0V DC
Pin Pin 3 (White) Torque Voltage 1.5V at rest -> 3.5V max
Pin Pin 4 (Yellow) Cadence Signal Digital Pulse Stream

Frequently Asked Questions

What does Tenways Error Fault 01 mean?

Mivice Torque Sensor Pulse / Offset Irregularity on Tenways Mivice Drive System (CGO600, CGO800S, AGO X). Symptoms include Smooth belt drive assistance stops working; OLED screen shows Fault 01.. The root fault is: Bottom bracket integrated Mivice torque sensor cable dislodged or zero-offset drifted outside factory tolerances.

How do I diagnose and fix Tenways Error Fault 01?

Power cycle bike without touching pedals. Trace the thin sensor wire coming from bottom bracket down into frame port. Verify bottom bracket has no lateral play; tighten bottom bracket lockring if loose. Check smartphone app for Mivice firmware recalibration function.

What multimeter voltage should I read during testing?

Target voltage is +5.0V DC. Follow the test procedure: Measure voltage between Pin 2 and Pin 3 while resting. Voltage must be steady at 1.5V +/- 0.1V.