Jasion Error Code E24 Fix & Diagnostic Guide

Motor Hall Sensor Pulse Intermittent / Missing Pulse — Jasion Motor Rotor Magnetic Position Sensing

Severity: Warning (Assistance Reduced) • Difficulty: 15-min DIY Workshop • Voltage Target: 0V / 5V pulse

Fault Symptoms & Root Cause

Symptoms: Motor stumbles at specific wheel angles, makes a clunking noise under load, or cuts in and out with 'E24' or 'Error 24'.

Primary Cause: One Hall sensor is failing intermittently, or the Hall signal connector has high contact resistance or moisture contamination.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Unplug Julet 9-pin motor connector and clean with electronic contact cleaner spray.
  2. Check cable tension along chainstay: ensure cable is not pulled tight when rear suspension compresses (on EB7 and X-Hunter).
  3. Rotate wheel slowly and observe display speedometer: if speed reads 0 or fluctuates wildly, the internal speed hall sensor or harness is damaged.
  4. If connector is clean and intact, internal Hall sensor IC in motor stator needs replacement or motor replacement.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Check for clean 5V amplitude on all three Hall signal wires.

Required Diagnostic Tools: Digital Multimeter

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Hall A (Yellow) Phase A Rotor Sensor 0V / 5V pulse
Pin Hall B (Green) Phase B Rotor Sensor 0V / 5V pulse
Pin Hall C (Blue) Phase C Rotor Sensor 0V / 5V pulse

Frequently Asked Questions

What does Jasion Error E24 mean?

Motor Hall Sensor Pulse Intermittent / Missing Pulse on Jasion Motor Rotor Magnetic Position Sensing. Symptoms include Motor stumbles at specific wheel angles, makes a clunking noise under load, or cuts in and out with 'E24' or 'Error 24'.. The root fault is: One Hall sensor is failing intermittently, or the Hall signal connector has high contact resistance or moisture contamination.

How do I diagnose and fix Jasion Error E24?

Unplug Julet 9-pin motor connector and clean with electronic contact cleaner spray. Check cable tension along chainstay: ensure cable is not pulled tight when rear suspension compresses (on EB7 and X-Hunter). Rotate wheel slowly and observe display speedometer: if speed reads 0 or fluctuates wildly, the internal speed hall sensor or harness is damaged. If connector is clean and intact, internal Hall sensor IC in motor stator needs replacement or motor replacement.

What multimeter voltage should I read during testing?

Target voltage is 0V / 5V pulse. Follow the test procedure: Check for clean 5V amplitude on all three Hall signal wires.

Other Jasion Error Codes

Jasion E06
Battery Under-Voltage Protection (LVC) / Deep Discharge
Jasion E07
Motor Hall Sensor Malfunction / Rotor Position Signal Lost
Jasion E08
Throttle Signal Malfunction / Wiper Out of Normal Range
Jasion E09
Motor Controller Hardware Failure / Blown Phase MOSFET
Jasion E10
Display Communication Receiving Fault (UART RX Timeout)
Jasion E11
Display Communication Transmission Fault (UART TX Error)