Kingbull Error Code E37 Fix & Diagnostic Guide

Brake Cutoff Switch Abnormality / Sensor Calibration Error — Kingbull Hydraulic Brake Sensor Circuit & Display Interface

Severity: Warning (Assistance Disabled) • Difficulty: 5-min Trailside • Voltage Target: Open when released

Fault Symptoms & Root Cause

Symptoms: Kingbull display shows 'E37' or 'Error 37'; motor power is inhibited even though brake levers appear released.

Primary Cause: A brake cutoff sensor is damaged or disconnected, or the display firmware has encountered a calibration mismatch with the brake sensor input lines. If both brake sensor cables are unplugged and E37 still displays, a display P16 factory reset is required.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Unplug both 2-pin red brake sensor connectors near the handlebars.
  2. If E37 immediately disappears, plug them in one by one to determine which brake sensor is sticking or defective.
  3. If E37 still appears on the display even with both brake cables completely disconnected, the display requires a factory reset:
  4. Press and hold [+] and [-] buttons simultaneously for 3 seconds to access the P-settings menu.
  5. Press the power button to advance through the parameters until you reach P16.
  6. Press and hold the [-] button for 5 full seconds until the display flashes, resetting the unit back to factory calibration defaults.
  7. Power cycle the bike. The E37 error will now be cleared.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Check for 0Ω short across disconnected brake cables. Replace lever switch if shorted while lever is resting.

Required Diagnostic Tools: 2.5mm / 3mm Hex Key

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Left Brake Cutoff 2-Pin Red Julet Open when released
Pin Right Brake Cutoff 2-Pin Red Julet Open when released
Pin P16 Factory Reset Firmware Reset Routine Hold [-] 5s

Frequently Asked Questions

What does Kingbull Error E37 mean?

Brake Cutoff Switch Abnormality / Sensor Calibration Error on Kingbull Hydraulic Brake Sensor Circuit & Display Interface. Symptoms include Kingbull display shows 'E37' or 'Error 37'; motor power is inhibited even though brake levers appear released.. The root fault is: A brake cutoff sensor is damaged or disconnected, or the display firmware has encountered a calibration mismatch with the brake sensor input lines. If both brake sensor cables are unplugged and E37 still displays, a display P16 factory reset is required.

How do I diagnose and fix Kingbull Error E37?

Unplug both 2-pin red brake sensor connectors near the handlebars. If E37 immediately disappears, plug them in one by one to determine which brake sensor is sticking or defective. If E37 still appears on the display even with both brake cables completely disconnected, the display requires a factory reset: Press and hold [+] and [-] buttons simultaneously for 3 seconds to access the P-settings menu. Press the power button to advance through the parameters until you reach P16. Press and hold the [-] button for 5 full seconds until the display flashes, resetting the unit back to factory calibration defaults. Power cycle the bike. The E37 error will now be cleared.

What multimeter voltage should I read during testing?

Target voltage is Open when released. Follow the test procedure: Check for 0Ω short across disconnected brake cables. Replace lever switch if shorted while lever is resting.

Other Kingbull Error Codes

Kingbull E00
System Status Normal / All Sensors Operational
Kingbull E06
Battery Under-Voltage Protection (LVC) / Deep Discharge Cutoff
Kingbull E07
Motor Hardware Fault / Phase & Connector Disconnect
Kingbull E08
Throttle Signal Fault / Accelerator Hall Sensor Out of Range
Kingbull E09
Motor Controller Hardware Fault / Power MOSFET Bridge Failure
Kingbull E10
Display Communication Receive Fault (Display RX Failure)