Lectric Error Code Error 24 Fix & Diagnostic Guide
Motor Hall Sensor Abnormality / Rotor Position Signal Lost — Lectric XP 1.0 / 2.0 / 3.0 / 4.0 / XP Lite / XPedition / XPeak
Fault Symptoms & Root Cause
Symptoms: Display flashes "Error 24" or "E24"; motor makes a loud stuttering, grinding noise and shudders without spinning smoothly; assist shuts down.
Primary Cause: The motor controller is not receiving rotor position signals from one or more of the 3 internal Hall effect sensors inside the rear hub motor. Often caused by water in the 9-pin motor connector, a bent pin, or a blown Hall IC.
Step-by-Step DIY Diagnostic & Repair Protocol
- Power off the bike. Locate the 9-pin motor cable connector on the chainstay.
- Disconnect and inspect the 5 small pins inside the connector for bent or broken pins.
- Dry thoroughly if wet and spray with electrical contact cleaner.
- Push firmly back together, aligning the molded arrows until completely flush.
- Test motor operation by lifting the rear wheel and gently applying throttle.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Connect black probe to Hall GND and red probe to Hall A/B/C signal pin with bike ON. Slowly rotate rear wheel backward by hand: voltage on each signal pin must toggle cleanly between ~0V and ~5V. If any signal stays at 0V or 5V constantly, that Hall sensor is dead.
Required Diagnostic Tools: Digital Multimeter with Needle Probes
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Small Red | Hall 5V VCC Supply | 4.8V - 5.1V DC |
| Pin Small Black | Hall Ground | 0.0V Ground |
| Pin Small Yellow, Green, Blue | Hall A, B, C Signals | 0V / 5V toggle when rotating wheel |
Frequently Asked Questions
What does Lectric Error Error 24 mean?
Motor Hall Sensor Abnormality / Rotor Position Signal Lost on Lectric XP 1.0 / 2.0 / 3.0 / 4.0 / XP Lite / XPedition / XPeak. Symptoms include Display flashes "Error 24" or "E24"; motor makes a loud stuttering, grinding noise and shudders without spinning smoothly; assist shuts down.. The root fault is: The motor controller is not receiving rotor position signals from one or more of the 3 internal Hall effect sensors inside the rear hub motor. Often caused by water in the 9-pin motor connector, a bent pin, or a blown Hall IC.
How do I diagnose and fix Lectric Error Error 24?
Power off the bike. Locate the 9-pin motor cable connector on the chainstay. Disconnect and inspect the 5 small pins inside the connector for bent or broken pins. Dry thoroughly if wet and spray with electrical contact cleaner. Push firmly back together, aligning the molded arrows until completely flush. Test motor operation by lifting the rear wheel and gently applying throttle.
What multimeter voltage should I read during testing?
Target voltage is 4.8V - 5.1V DC. Follow the test procedure: Connect black probe to Hall GND and red probe to Hall A/B/C signal pin with bike ON. Slowly rotate rear wheel backward by hand: voltage on each signal pin must toggle cleanly between ~0V and ~5V. If any signal stays at 0V or 5V constantly, that Hall sensor is dead.
Other Lectric Error Codes
Motor Issue Detected / Motor Hall Sensor Signal Failure Lectric E010
Display Communication Reception Issue / RX Lost Lectric E008
Throttle Issue Detected / Throttle Signal Abnormality Lectric E001
Motor Phase Loss / Phase Wire Disconnection Lectric E002
Electronic Brake Cut-Off Active / Brake Sensor Stuck Lectric E003
Pedal Assist Sensor (PAS) Signal Issue / Cadence Dropout