Rad Power & Hub OEM Error Code Error 24 / E24 Fix & Diagnostic Guide
Motor Internal Hall Sensor Circuit Fault — Rad Power Bikes / Lectric / Engwe / Himiway / King-Meter Displays
Fault Symptoms & Root Cause
Symptoms: Display shows Error 24 / E24; throttle causes a quick jerk and immediate shutoff.
Primary Cause: Controller is not receiving rotor position pulses from one of the internal magnetic Hall sensors inside the hub motor.
Step-by-Step DIY Diagnostic & Repair Protocol
- Inspect the 9-pin quick-release plug near the rear dropouts: ensure it is pushed all the way past the molded notch line.
- Back-probe the thin Yellow, Green, and Blue Hall wires while supplying 5V to verify toggle voltage.
- If one Hall sensor is burnt, replace sensor board or swap controller for a dual-mode sensorless controller.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: With bike power ON, connect black meter probe to Black Hall ground. Probe thin Yellow, Green, then Blue wire while turning wheel by hand. Each must switch 0V to 5V. If one stays flat 0V or 5V, that Hall sensor IC is blown.
Required Diagnostic Tools: Digital Multimeter
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Red (Thin) | +5V Hall VCC Supply | 4.8V - 5.1V DC |
| Pin Black (Thin) | Hall Ground Reference | 0.0V Ground |
| Pin Yellow / Green / Blue (Thin) | Hall Phases A, B, C Signals | Toggles between 0.2V (Low) and 4.8V (High) |
Frequently Asked Questions
What does Rad Power & Hub OEM Error Error 24 / E24 mean?
Motor Internal Hall Sensor Circuit Fault on Rad Power Bikes / Lectric / Engwe / Himiway / King-Meter Displays. Symptoms include Display shows Error 24 / E24; throttle causes a quick jerk and immediate shutoff.. The root fault is: Controller is not receiving rotor position pulses from one of the internal magnetic Hall sensors inside the hub motor.
How do I diagnose and fix Rad Power & Hub OEM Error Error 24 / E24?
Inspect the 9-pin quick-release plug near the rear dropouts: ensure it is pushed all the way past the molded notch line. Back-probe the thin Yellow, Green, and Blue Hall wires while supplying 5V to verify toggle voltage. If one Hall sensor is burnt, replace sensor board or swap controller for a dual-mode sensorless controller.
What multimeter voltage should I read during testing?
Target voltage is 4.8V - 5.1V DC. Follow the test procedure: With bike power ON, connect black meter probe to Black Hall ground. Probe thin Yellow, Green, then Blue wire while turning wheel by hand. Each must switch 0V to 5V. If one stays flat 0V or 5V, that Hall sensor IC is blown.
Other Rad Power & Hub OEM Error Codes
Brake Cutoff Switch Tripped / Stuck Closed Rad Power & Hub OEM Error 22
Throttle Signal Abnormality / Stuck Throttle Rad Power & Hub OEM Error 21
Abnormally High Controller Current / Inverter Short Rad Power & Hub OEM Error 23 / E23
Motor Phase Line Short Circuit or Disconnection Rad Power & Hub OEM Error 21 / Error 01 / E1
Rad Power Throttle Voltage Sensor Signal Abnormality Rad Power & Hub OEM Error 30 / E30
Display to Controller Communication Loss