Shimano STEPS Error Code E013 Fix & Diagnostic Guide

Drive Unit Internal Sensor Hardware Anomaly — EP8 / EP6 / E8000 / E6100

Severity: Critical (Fatal Drive Stop) • Difficulty: Certified Shop Required • Voltage Target: SM-PCE02 Link Active

Fault Symptoms & Root Cause

Symptoms: Motor assist cuts out; display shows E013 and beeps persistently.

Primary Cause: Internal drive unit electronic control unit detected an internal torque or angular cadence sensor hardware failure.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Perform hard reset: power down, disconnect main battery for 60 seconds, reconnect and power up.
  2. Connect to Shimano E-TUBE PROJECT Cyclo on smartphone or PC via SM-PCE02 USB interface.
  3. Check error log and attempt a firmware re-flash of the drive unit (DU-EP801 / DU-EP800).
  4. If fault code remains persistent, drive unit replacement under Shimano warranty is required.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Use Shimano E-TUBE PROJECT software to run drive unit self-diagnostic and verify sensor voltage rails.

Required Diagnostic Tools: Shimano SM-PCE02 PC Link Interface

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin E-Tube Port Diagnostic Telemetry Port SM-PCE02 Link Active

Frequently Asked Questions

What does Shimano STEPS Error E013 mean?

Drive Unit Internal Sensor Hardware Anomaly on EP8 / EP6 / E8000 / E6100. Symptoms include Motor assist cuts out; display shows E013 and beeps persistently.. The root fault is: Internal drive unit electronic control unit detected an internal torque or angular cadence sensor hardware failure.

How do I diagnose and fix Shimano STEPS Error E013?

Perform hard reset: power down, disconnect main battery for 60 seconds, reconnect and power up. Connect to Shimano E-TUBE PROJECT Cyclo on smartphone or PC via SM-PCE02 USB interface. Check error log and attempt a firmware re-flash of the drive unit (DU-EP801 / DU-EP800). If fault code remains persistent, drive unit replacement under Shimano warranty is required.

What multimeter voltage should I read during testing?

Target voltage is SM-PCE02 Link Active. Follow the test procedure: Use Shimano E-TUBE PROJECT software to run drive unit self-diagnostic and verify sensor voltage rails.

Other Shimano STEPS Error Codes

Shimano STEPS W013
Torque Sensor Startup Calibration Warning
Shimano STEPS E010
System Hardware General Error / Battery Terminal Drop
Shimano STEPS W011
Speed Sensor Signal Missing / Alignment
Shimano STEPS E020
E-Tube CAN Bus Communication Loss between Battery and DU
Shimano STEPS E012
Torque Sensor Initialization Error (Foot on Pedal on Boot)
Shimano STEPS E014
Torque Sensor Offset Zero-Point Out of Range