Shimano STEPS Error Code E021 Fix & Diagnostic Guide

Battery to Drive Unit Communication Failure — BT-E8010 / BT-E8016 / BT-E8035 / BT-E8036 / Darfon / Trendpower

Severity: Critical (Fatal Drive Stop) • Difficulty: 10-min Workshop • Voltage Target: 36V - 42V DC

Fault Symptoms & Root Cause

Symptoms: Display shows E021; system powers off automatically after 15 seconds.

Primary Cause: The drive unit is unable to communicate with the battery BMS over the CAN bus / BM-E80xx mount terminals.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Remove battery from bike frame and inspect the gold terminal connector blades.
  2. Clean oxidation or road grime using electrical contact cleaner and a clean microfibre cloth.
  3. Inspect spring tension on battery frame mount: ensure battery locks into place with an audible click and no wobble.
  4. Check the BM-E80xx mount wiring harness leading down to the motor for pinches.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure voltage between Pin 1 and Pin 2 on battery terminals with power switched on. Check continuity on CAN wires from mount to motor.

Required Diagnostic Tools: Electrical Contact Cleaner Spray

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (+) Main DC Power Positive 36V - 42V DC
Pin Pin 2 (-) Main DC Power Ground 0.0V DC
Pin Pin 3 (CAN-H) Battery BMS CAN High 2.5V DC
Pin Pin 4 (CAN-L) Battery BMS CAN Low 2.5V DC
Pin Pin 5 (P-ON) Power-On Signal Line 5V DC Wake Signal

Frequently Asked Questions

What does Shimano STEPS Error E021 mean?

Battery to Drive Unit Communication Failure on BT-E8010 / BT-E8016 / BT-E8035 / BT-E8036 / Darfon / Trendpower. Symptoms include Display shows E021; system powers off automatically after 15 seconds.. The root fault is: The drive unit is unable to communicate with the battery BMS over the CAN bus / BM-E80xx mount terminals.

How do I diagnose and fix Shimano STEPS Error E021?

Remove battery from bike frame and inspect the gold terminal connector blades. Clean oxidation or road grime using electrical contact cleaner and a clean microfibre cloth. Inspect spring tension on battery frame mount: ensure battery locks into place with an audible click and no wobble. Check the BM-E80xx mount wiring harness leading down to the motor for pinches.

What multimeter voltage should I read during testing?

Target voltage is 36V - 42V DC. Follow the test procedure: Measure voltage between Pin 1 and Pin 2 on battery terminals with power switched on. Check continuity on CAN wires from mount to motor.

Other Shimano STEPS Error Codes

Shimano STEPS W013
Torque Sensor Startup Calibration Warning
Shimano STEPS E010
System Hardware General Error / Battery Terminal Drop
Shimano STEPS W011
Speed Sensor Signal Missing / Alignment
Shimano STEPS E020
E-Tube CAN Bus Communication Loss between Battery and DU
Shimano STEPS E012
Torque Sensor Initialization Error (Foot on Pedal on Boot)
Shimano STEPS E014
Torque Sensor Offset Zero-Point Out of Range