Shimano STEPS Error Code E042 Fix & Diagnostic Guide

E-Tube Junction Box Communication Loss — EP801 / EP800 / E8000 / E7000 / E6100

Severity: Warning (Assistance Reduced) • Difficulty: 15-min DIY Workshop • Voltage Target: 0.0V DC

Fault Symptoms & Root Cause

Symptoms: Multiple components not recognized in E-Tube Project app.

Primary Cause: SM-JC41 internal junction B box corroded by water ingress inside seat tube.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Inspect Shimano E-Tube EW-SD50 or EW-SD300 wiring for E042 loose seating.
  2. Use TL-EW300 connection tool to firmly snap connectors until tactile click is felt.
  3. Clear any foot pressure from pedals and power cycle system using battery button.
  4. Connect bike to Shimano E-TUBE PROJECT app to read detailed diagnostic freeze-frame.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Shimano E-Tube bus carries 12V DC bus voltage and proprietary multiplexed CAN signal. Measure 11.5V - 12.8V between terminal pins at junction box.

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Outer Shield / Pin 1 Ground Reference 0.0V DC
Pin Center Core / Pin 2 12V Bus Power & Serial Data 11.8V - 12.6V DC

Frequently Asked Questions

What does Shimano STEPS Error E042 mean?

E-Tube Junction Box Communication Loss on EP801 / EP800 / E8000 / E7000 / E6100. Symptoms include Multiple components not recognized in E-Tube Project app.. The root fault is: SM-JC41 internal junction B box corroded by water ingress inside seat tube.

How do I diagnose and fix Shimano STEPS Error E042?

Inspect Shimano E-Tube EW-SD50 or EW-SD300 wiring for E042 loose seating. Use TL-EW300 connection tool to firmly snap connectors until tactile click is felt. Clear any foot pressure from pedals and power cycle system using battery button. Connect bike to Shimano E-TUBE PROJECT app to read detailed diagnostic freeze-frame.

What multimeter voltage should I read during testing?

Target voltage is 0.0V DC. Follow the test procedure: Shimano E-Tube bus carries 12V DC bus voltage and proprietary multiplexed CAN signal. Measure 11.5V - 12.8V between terminal pins at junction box.

Other Shimano STEPS Error Codes

Shimano STEPS W013
Torque Sensor Startup Calibration Warning
Shimano STEPS E010
System Hardware General Error / Battery Terminal Drop
Shimano STEPS W011
Speed Sensor Signal Missing / Alignment
Shimano STEPS E020
E-Tube CAN Bus Communication Loss between Battery and DU
Shimano STEPS E012
Torque Sensor Initialization Error (Foot on Pedal on Boot)
Shimano STEPS E014
Torque Sensor Offset Zero-Point Out of Range