TQ Error Code E11 Fix & Diagnostic Guide
Motor Inverter Phase B Gate Undervoltage — HPR50 / HPR 120S
Fault Symptoms & Root Cause
Symptoms: Motor clicks and shuts off.
Primary Cause: Gate driver charge pump failure.
Step-by-Step DIY Diagnostic & Repair Protocol
- Inspect TQ wiring harness connectors for E11.
- Separate waterproof connectors, inspect pins, and ensure tight reconnection.
- Check 5V reference supply and battery voltage with digital multimeter.
- Power cycle system completely to clear transient protection flags.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Measure 5V sensor power between Red and Black wires. Signal pins must read clean logic levels or toggle during rotation.
Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Pin 1 (Red) | VCC System Power | 5.0V DC Sensor / Logic Rail |
| Pin Pin 2 (Black) | Ground Reference | 0.0V Ground |
| Pin Pin 3 (Blue/Yellow) | Signal Data Line | CAN / PWM Signal Toggle |
Frequently Asked Questions
What does TQ Error E11 mean?
Motor Inverter Phase B Gate Undervoltage on HPR50 / HPR 120S. Symptoms include Motor clicks and shuts off.. The root fault is: Gate driver charge pump failure.
How do I diagnose and fix TQ Error E11?
Inspect TQ wiring harness connectors for E11. Separate waterproof connectors, inspect pins, and ensure tight reconnection. Check 5V reference supply and battery voltage with digital multimeter. Power cycle system completely to clear transient protection flags.
What multimeter voltage should I read during testing?
Target voltage is 5.0V DC Sensor / Logic Rail. Follow the test procedure: Measure 5V sensor power between Red and Black wires. Signal pins must read clean logic levels or toggle during rotation.
Other TQ Error Codes
Speed Pulse Interrupt TQ E032
Torque & Cadence Sensor Calibration Timeout TQ E01 / E01-01
Torque & Cadence Sensor Zero-Offset Calibration Drift TQ E22
Remote Handlebar Switch & OLED Display CAN Timeout TQ E005 / E05
Torque & Cadence Sensor Initialization Failure TQ 0496 / ERR 0496
DRV HW Drive Unit Phase Break / Motor Stator Fault