Brose Error Code 26 Fix & Diagnostic Guide

Battery Low Ambient Temperature Charging Lockout — Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2

Severity: Informational / Warning • Difficulty: 5-min Trailside • Voltage Target: 11.5V - 13.0V DC

Fault Symptoms & Root Cause

Symptoms: Battery refuses to charge in unheated shed.

Primary Cause: Cell temperature below 0°C; charging disabled to prevent lithium plating.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Inspect Brose motor wiring harness connectors and display leads for 26.
  2. Inspect internal drive belt condition through motor inspection port if belt slip is suspected.
  3. Check battery Rosenberger / CAN connection pins for dirt and oxidation.
  4. Update motor firmware using Brose Service Tool via certified dealer.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).

Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Pin 1 (Red) 12V Bus Power 11.5V - 13.0V DC
Pin Pin 2 (Black) Ground Reference 0.0V DC Ground
Pin Pin 3 (White) CAN High 2.4V - 2.8V DC
Pin Pin 4 (Blue) CAN Low 2.1V - 2.5V DC

Frequently Asked Questions

What does Brose Error 26 mean?

Battery Low Ambient Temperature Charging Lockout on Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2. Symptoms include Battery refuses to charge in unheated shed.. The root fault is: Cell temperature below 0°C; charging disabled to prevent lithium plating.

How do I diagnose and fix Brose Error 26?

Inspect Brose motor wiring harness connectors and display leads for 26. Inspect internal drive belt condition through motor inspection port if belt slip is suspected. Check battery Rosenberger / CAN connection pins for dirt and oxidation. Update motor firmware using Brose Service Tool via certified dealer.

What multimeter voltage should I read during testing?

Target voltage is 11.5V - 13.0V DC. Follow the test procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).

Other Brose Error Codes

Brose 001 / C180
Motor Stator Temperature Thermal Cutoff
Brose 006
Speed Sensor Input Timeout Fault
Brose 30
Display Communication Lost
Brose 101
Battery Pack Discharge Undervoltage Protection Cutoff
Brose 201
CAN-Bus Frame Communication Heartbeat Timeout
Brose 10
Torque Sensor Signal Drift