Brose Error Code 60 Fix & Diagnostic Guide
CAN Communication Line Frame Error Rate High — Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2
Fault Symptoms & Root Cause
Symptoms: Display lags and intermittently drops data.
Primary Cause: Twisted pair CAN leads damaged.
Step-by-Step DIY Diagnostic & Repair Protocol
- Inspect Brose motor wiring harness connectors and display leads for 60.
- Inspect internal drive belt condition through motor inspection port if belt slip is suspected.
- Check battery Rosenberger / CAN connection pins for dirt and oxidation.
- Update motor firmware using Brose Service Tool via certified dealer.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).
Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Pin 1 (Red) | 12V Bus Power | 11.5V - 13.0V DC |
| Pin Pin 2 (Black) | Ground Reference | 0.0V DC Ground |
| Pin Pin 3 (White) | CAN High | 2.4V - 2.8V DC |
| Pin Pin 4 (Blue) | CAN Low | 2.1V - 2.5V DC |
Frequently Asked Questions
What does Brose Error 60 mean?
CAN Communication Line Frame Error Rate High on Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2. Symptoms include Display lags and intermittently drops data.. The root fault is: Twisted pair CAN leads damaged.
How do I diagnose and fix Brose Error 60?
Inspect Brose motor wiring harness connectors and display leads for 60. Inspect internal drive belt condition through motor inspection port if belt slip is suspected. Check battery Rosenberger / CAN connection pins for dirt and oxidation. Update motor firmware using Brose Service Tool via certified dealer.
What multimeter voltage should I read during testing?
Target voltage is 11.5V - 13.0V DC. Follow the test procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).