Brose Error Code 72 Fix & Diagnostic Guide
Cadence Hall Sensor Magnet Ring Decoupled — Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2
Fault Symptoms & Root Cause
Symptoms: Motor assist pulses rhythmically.
Primary Cause: Cadence magnet ring debonded from spindle.
Step-by-Step DIY Diagnostic & Repair Protocol
- Inspect Brose motor wiring harness connectors and display leads for 72.
- Inspect internal drive belt condition through motor inspection port if belt slip is suspected.
- Check battery Rosenberger / CAN connection pins for dirt and oxidation.
- Update motor firmware using Brose Service Tool via certified dealer.
Multimeter Testing & Bench Specs
Multimeter Test Procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).
Required Diagnostic Tools: Digital Multimeter & Precision Hex/Torx Set
Wiring Pinout & Expected DC Values
| Pin | Function | Target Voltage / Signal Spec |
|---|---|---|
| Pin Pin 1 (Red) | 12V Bus Power | 11.5V - 13.0V DC |
| Pin Pin 2 (Black) | Ground Reference | 0.0V DC Ground |
| Pin Pin 3 (White) | CAN High | 2.4V - 2.8V DC |
| Pin Pin 4 (Blue) | CAN Low | 2.1V - 2.5V DC |
Frequently Asked Questions
What does Brose Error 72 mean?
Cadence Hall Sensor Magnet Ring Decoupled on Drive S Mag / Drive T / Drive C / Specialized 2.1 & 2.2. Symptoms include Motor assist pulses rhythmically.. The root fault is: Cadence magnet ring debonded from spindle.
How do I diagnose and fix Brose Error 72?
Inspect Brose motor wiring harness connectors and display leads for 72. Inspect internal drive belt condition through motor inspection port if belt slip is suspected. Check battery Rosenberger / CAN connection pins for dirt and oxidation. Update motor firmware using Brose Service Tool via certified dealer.
What multimeter voltage should I read during testing?
Target voltage is 11.5V - 13.0V DC. Follow the test procedure: Measure Brose Marquardt display port: Pin 1 (12V VCC), Pin 2 (GND), Pin 3 (CAN-H 2.5V), Pin 4 (CAN-L 2.4V).