Fault Symptoms & Root Cause

Symptoms: Loud humming / groaning noise from rear hub motor when starting from a stop, severe hesitation, Error 24 on screen.

Primary Cause: One or more of the 3 internal bipolar Hall effect sensors (41F / 041) inside the motor hub failed or lost 5V signal.

Step-by-Step DIY Diagnostic & Repair Protocol

  1. Inspect 9-pin motor connector along rear chainstay for moisture or loose fit.
  2. Disconnect motor cable, inspect thin internal pins for pins pushed backward into rubber casing.
  3. Perform Multimeter 5V Hall Test (see schematic below).
  4. If controller supports sensorless mode, cycle pedal assist; otherwise replace motor hall sensor board or motor assembly.

Multimeter Testing & Bench Specs

Multimeter Test Procedure: Power bike on. Probe black wire and each color (Yellow, Green, Blue) while slowly rotating rear wheel backwards by hand. Each pin MUST cleanly alternate between 0.0V and 4.8V. A pin stuck at 0V or 5V indicates a dead Hall sensor.

Required Diagnostic Tools: Digital Multimeter with Needle Probes

Wiring Pinout & Expected DC Values

Pin Function Target Voltage / Signal Spec
Pin Thin Red Hall 5V Supply 4.5V - 5.0V DC
Pin Thin Black Hall Ground 0.0V DC
Pin Thin Yellow Hall A Signal Toggles 0V to 5V when wheel rotated backwards by hand
Pin Thin Green Hall B Signal Toggles 0V to 5V when wheel rotated backwards by hand
Pin Thin Blue Hall C Signal Toggles 0V to 5V when wheel rotated backwards by hand

Frequently Asked Questions

What does Rad Power & Hub OEM Error Error 24 mean?

Motor Hall Sensor Signal Failure (Commutation Lost) on RadRover / RadCity / RadRunner / RadWagon / RadMission. Symptoms include Loud humming / groaning noise from rear hub motor when starting from a stop, severe hesitation, Error 24 on screen.. The root fault is: One or more of the 3 internal bipolar Hall effect sensors (41F / 041) inside the motor hub failed or lost 5V signal.

How do I diagnose and fix Rad Power & Hub OEM Error Error 24?

Inspect 9-pin motor connector along rear chainstay for moisture or loose fit. Disconnect motor cable, inspect thin internal pins for pins pushed backward into rubber casing. Perform Multimeter 5V Hall Test (see schematic below). If controller supports sensorless mode, cycle pedal assist; otherwise replace motor hall sensor board or motor assembly.

What multimeter voltage should I read during testing?

Target voltage is 4.5V - 5.0V DC. Follow the test procedure: Power bike on. Probe black wire and each color (Yellow, Green, Blue) while slowly rotating rear wheel backwards by hand. Each pin MUST cleanly alternate between 0.0V and 4.8V. A pin stuck at 0V or 5V indicates a dead Hall sensor.

Other Rad Power & Hub OEM Error Codes

Rad Power & Hub OEM Error 25
Brake Cutoff Switch Tripped / Stuck Closed
Rad Power & Hub OEM Error 22
Throttle Signal Abnormality / Stuck Throttle
Rad Power & Hub OEM Error 24 / E24
Motor Internal Hall Sensor Circuit Fault
Rad Power & Hub OEM Error 21
Abnormally High Controller Current / Inverter Short
Rad Power & Hub OEM Error 23 / E23
Motor Phase Line Short Circuit or Disconnection
Rad Power & Hub OEM Error 21 / Error 01 / E1
Rad Power Throttle Voltage Sensor Signal Abnormality